HK 92RD 04 BG2

Gear flow divider, group 2 92RD 4-way

Gear flow divider, group 2 92RD 4-way

Design
without central phase compensation valves 
internal leak oil discharge 
Pressure difference
max. 30 bar (between the sections) 
Construction type
4 sections 
Prenos datoteke PDF
Register now to get access to our online shop

Register now and access our complete product range and many exclusive services.

Lastnosti

Design
  • without central phase compensation valves 
  • internal leak oil discharge 
Pressure difference
  • max. 30 bar (between the sections) 
Construction type
  • 4 sections 
Size
  • group 4 
Customs tariff number
  • 84122981 
Vse lastnosti

Product description

Opombe
Before commissioning the system, the first running-in of the gear flow divider should be under no load.
Diagrams and circuit diagrams essentially valid as schematic diagrams also for 4-way flow dividers.
Opis
This flow divider is used to supply four independent hydraulic circuits with just one pump.
Division error approx. 3 %.
This flow divider is used to supply two independent hydraulic circuits with just one pump.
Configuration of gear flow dividers: qi = Q/z * 1000/n.
Qi = displacement/section [cm³].
Q = total input volume flow [l/min].
Z = number of sections.
N = rotating speed [rpm].
Dodatne informacije
Recommended speed: 1800 - 2000 rpm

Product variants

5 Results
Prikaz dimenzijske risbe
Oznaka
p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
p1 = max. working pressure
p2 = max. peak pressure

Column selection

p1 max. (bar)
p2 max. (bar)
Flow per element min. (l/min)
Flow per element rec'd (l/min)
Flow per element max. (l/min)
Input volume per section (cm³)
A (mm)
Li (mm)
p1 = max. working pressure
p2 = max. peak pressure