HK PCFC 12 NS0 15

2-W flow control valve Cartr Sz12 28-57L
Q max.
90 l/min
Q min.
57 l/min
A
49.8 mm
Prenos datoteke PDF
Zdaj se registrirajte, da boste lahko dostopali do naše spletne trgovine.

Register now and access our complete product range and many exclusive services.

Podrobnosti o izdelku za

HK PCFC 12 NS0 15

Q max.
90 l/min
Q min.
57 l/min
A
49.8 mm
B
44.5 mm
Screw-in hole
SAE 12/2
Screw-in housing
HK GEH 12 C 1220 HK GEH 34 C 1220
Screw-in thread
UNF 1.1/16″ -12 -2B
Setting range with Qon max.
57 l/min
Setting range with Qon min.
28.5 l/min
Vse lastnosti

Lastnosti

Max. working pressure
  • max. 300 bar 
Design
  • pressure-compensated 
Customs tariff number
  • 84812010 

Opis izdelka

Opombe
These valves must be set according to the application.
Tightening torque for valve size 08 with aluminium housing: 34-41 Nm
Tightening torque for valve size 08 with steel housing: 47 - 54 Nm
Tightening torque for valve size 10 with aluminium housing: 47-54 Nm
Tightening torque for valve size 10 with steel housing: 74 - 81 Nm
Tightening torque for valve size 12 with aluminium housing: 74-81 Nm
Tightening torque for valve size 12 with steel housing: 95 - 102 Nm
SAE screw-in bores of Cartridge valves from different manufacturers may differ slightly, e.g., in the depth and diameter of the valve seat, even if the screw-in thread is the same. For this reason, it is essential that all relevant dimensions are compared with the technical data of the screw-in bore must be compared.
Opis
Setting via setscrew.
Max. deviation: 5 %.
Only adjust valves in depressurized state!

Product variants

3 Results
Prikaz dimenzijske risbe
Oznaka
Q maks. (l/min)
Q min. (l/min)
A (mm)
B (mm)
Qein = intake volumetric flow
Qmax - max. intake volumetric flow
Qmin - min. volumetric flow for control function

Column selection

Q maks. (l/min)
Q min. (l/min)
A (mm)
B (mm)
Območje nastavitve pri Qein maks. (l/min)
Območje nastavitve pri Qein min. (l/min)
Odprtina za vijačenje
Uvojni navoj
Uvojno ohišje
Qein = intake volumetric flow
Qmax - max. intake volumetric flow
Qmin - min. volumetric flow for control function