HK BFCV 08 NS0 02

3-pot.vent.za reg.pret. Cartr. NV8 3-8L
Q maks.
22 l/min
Q min.
8 l/min
A
41 mm
Prenos datoteke PDF
Zdaj se registrirajte, da boste lahko dostopali do naše spletne trgovine.

Register now and access our complete product range and many exclusive services.

Podrobnosti o izdelku za

HK BFCV 08 NS0 02

Q maks.
22 l/min
Q min.
8 l/min
A
41 mm
B
40 mm
Območje nastavitve pri Qein maks.
8 l/min
Območje nastavitve pri Qein min.
4 l/min
Screw-in hole
SAE 08/3
Screw-in thread
UNF 3/4″ -16 -2B
Screw-in housing
HK GEH 38 C 0830
Vse lastnosti

Lastnosti

maks. delovni tlak
  • maks. 300 bar 
Izvedba
  • s tlačno kompenzacijo 
Številka carinske tarife
  • 84812010 

Opis izdelka

Opombe
These valves must be set according to the application.
Tightening torque for valve size 08 with aluminium housing: 34-41 Nm
Tightening torque for valve size 08 with steel housing: 47 - 54 Nm
Tightening torque for valve size 10 with aluminium housing: 47-54 Nm
Tightening torque for valve size 10 with steel housing: 74 - 81 Nm
Tightening torque for valve size 12 with aluminium housing: 74-81 Nm
Tightening torque for valve size 12 with steel housing: 95 - 102 Nm
SAE screw-in bores of Cartridge valves from different manufacturers may differ slightly, e.g., in the depth and diameter of the valve seat, even if the screw-in thread is the same. For this reason, it is essential that all relevant dimensions are compared with the technical data of the screw-in bore must be compared.
Opis
Max. deviation: 5 %.
Setting via setscrew.
Residual oil flow at outlet 2 can be pressurized.
Only adjust valves in depressurized state!

Product variants

4 Results
Prikaz dimenzijske risbe
Oznaka
Q max. (l/min)
Q min. (l/min)
A (mm)
B (mm)
Qein = intake volumetric flow
Qmax - max. intake volumetric flow
Qmin - min. volumetric flow for control function

Column selection

Q max. (l/min)
Q min. (l/min)
A (mm)
B (mm)
Screw-in hole
Screw-in housing
Screw-in thread
Setting range with Qon max. (l/min)
Setting range with Qon min. (l/min)
Qein = intake volumetric flow
Qmax - max. intake volumetric flow
Qmin - min. volumetric flow for control function